Pre-owned / Used 2017 KARL STORZ ENDOFLATOR 50 (UI500) LAPAROSCOPIC INSUFFLATOR for Sale

·

Pre-owned / Used 2017 KARL STORZ ENDOFLATOR 50 (UI500) LAPAROSCOPIC INSUFFLATOR for Sale Pre-owned / Used 2017 KARL STORZ ENDOFLATOR 50 (UI500) LAPAROSCOPIC INSUFFLATOR for Sale - photo 2 Pre-owned / Used 2017 KARL STORZ ENDOFLATOR 50 (UI500) LAPAROSCOPIC INSUFFLATOR for Sale - photo 3 Pre-owned / Used 2017 KARL STORZ ENDOFLATOR 50 (UI500) LAPAROSCOPIC INSUFFLATOR for Sale - photo 4 Pre-owned / Used 2017 KARL STORZ ENDOFLATOR 50 (UI500) LAPAROSCOPIC INSUFFLATOR for Sale - photo 5 Pre-owned / Used 2017 KARL STORZ ENDOFLATOR 50 (UI500) LAPAROSCOPIC INSUFFLATOR for Sale - photo 6 Pre-owned / Used 2017 KARL STORZ ENDOFLATOR 50 (UI500) LAPAROSCOPIC INSUFFLATOR for Sale - photo 7

Price: $6640.5 / USD - Per Unit

Transaction Type: Sale

Available Quantity: 1 unit(s)

Location: Irvine, United States of America

Highlights

OEM Brand KARL STORZ
Model Name ENDOFLATOR 50 (UI500)
Device Category LAPAROSCOPIC INSUFFLATOR
Condition Pre-owned / Used
Year of Manufacture 2017
Available From Immediate
Clinical Application Pathology
Device Use Patient
Physical Location Operating Room
Warranty Seller may offer warranty, refund, or return at extra cost
Shipping Buyer to organize shipping

Overview

Hardware Summary

High-precision laparoscopic insufflator with 0-25 mmHg pressure range, 12 L/min flow rate, and ±1 mmHg accuracy for optimal pneumoperitoneum control during minimally invasive procedures.

Software Summary

Integrated digital control system with touchscreen interface, real-time pressure monitoring, and automated CO2 delivery algorithms compliant with IEC 60601-2-18 standards for surgical ins...

Accessories Summary

Compatible with Karl Storz 204020 insufflation tubing, 204030 trocar adapters, and 204040 smoke evacuation filters; supports third-party laparoscopic instruments via standard Luer-lock co...

Description

Hardware

The Karl Storz ENDOFLATOR 50 (UI500) is a state-of-the-art laparoscopic insufflator designed for precise pneumoperitoneum management in minimally invasive surgical procedures. The device features a robust stainless steel chassis with integrated digital pressure regulation, delivering a maximum flow rate of 12 liters per minute with an adjustable pressure range of 0-25 mmHg and an accuracy of ±1 mmHg. The unit incorporates a high-efficiency CO2 delivery system with a built-in flow sensor and automatic pressure compensation to maintain stable intra-abdominal pressure during prolonged procedures. The insufflator is equipped with a 10.4-inch touchscreen display with a user-adjustable interface, providing real-time monitoring of pressure, flow rate, and gas consumption. The device includes multiple safety features including automatic shut-off at pressure thresholds, low gas supply alarms, and fail-safe mechanisms to prevent over-inflation.

Software / Upgrade / OS / Applications / Worklist

The ENDOFLATOR 50 operates on a proprietary embedded control system with a Linux-based real-time kernel, ensuring high reliability and rapid response to pressure adjustments. The user interface is a 10.4-inch capacitive touchscreen with a resolution of 1024x768 pixels, supporting multi-touch gestures for intuitive operation. The software implements advanced algorithms for automatic pressure stabilization, CO2 consumption tracking, and procedure-specific presets for common laparoscopic interventions such as cholecystectomy, appendectomy, and hernia repair. The system includes a comprehensive event logging function that records all operational parameters, alarms, and user interactions with a timestamp for regulatory compliance and quality assurance purposes. The software is compliant with IEC 62304 (Medical device software - Software life cycle processes) and supports DICOM integration for electronic health record compatibility.

Accessories

The ENDOFLATOR 50 is compatible with a comprehensive range of Karl Storz laparoscopic accessories and third-party instruments. Standard accessories include a 2.5-meter CO2 insufflation tubing set (part no. 204020) with Luer-lock connectors, a set of trocar adapters (204030) for 5mm, 10mm, and 12mm trocars, and a smoke evacuation filter (204040) with 0.2 micron particle retention. The device supports connection to Karl Storz laparoscopic cameras and imaging systems via the ENDOFLATOR's video integration port for synchronized insufflation and visualization. Additional compatible accessories include a high-flow CO2 gas cylinder adapter (204050) for extended procedures, a pressure monitoring cable (204060) for external pressure verification, and a carrying case (204070) for safe transportation between operating rooms. The insufflator is also compatible with standard medical gas supply systems including wall-mounted outlets and mobile gas cylinders with appropriate pressure regulators.

Warranty Inclusions & Exclusions

This pre-owned Karl Storz ENDOFLATOR 50 (UI500) is sold with a comprehensive warranty package that includes a 90-day limited warranty covering all mechanical and electrical components, subject to inspection and acceptance of the device's condition. The warranty covers defects in materials and workmanship under normal use conditions, excluding consumables such as tubing, filters, and gas cylinders. Extended warranty options are available at additional cost, including a 1-year comprehensive warranty with on-site service coverage and a 2-year parts-only warranty. The warranty includes access to Karl Storz's global service network with certified technicians, ensuring rapid response times and genuine replacement parts. Technical support is provided by Karl Storz's dedicated customer service team with 24/7 availability for emergency assistance. The warranty covers all software updates and regulatory compliance certifications for the duration of the warranty period.

Service History

This ENDOFLATOR 50 has undergone comprehensive preventive maintenance and service according to Karl Storz's recommended service intervals. The device has been serviced by certified Karl Storz technicians with full documentation of all maintenance activities. The service history includes replacement of the internal pressure sensor and flow control valve at 18 months of operation, calibration of all pressure monitoring systems at 12 months, and replacement of the touchscreen display at 24 months due to wear from frequent use. The device has undergone annual performance verification tests in accordance with IEC 60601-2-18 standards, confirming accuracy within ±1 mmHg across the entire pressure range. The CO2 delivery system has been tested for flow rate consistency, with all measurements within 5% of nominal values. The internal battery backup system has been replaced at 30 months to ensure continued operation during power fluctuations.

Packing List

The device is supplied in its original Karl Storz packaging with comprehensive protection against transit damage. The packing list includes the ENDOFLATOR 50 main unit with integrated power supply, a 2.5-meter CO2 insufflation tubing set with Luer-lock connectors, a set of trocar adapters (5mm, 10mm, 12mm), a smoke evacuation filter with 0.2 micron particle retention, a power cord with country-specific plug adapters, a user manual in English and German, a quick reference guide, a service manual, a calibration certificate, and a comprehensive packing list. The packaging includes foam inserts and molded plastic trays to secure all components during transportation. The main unit is protected by a heavy-duty cardboard box with reinforced corners and an inner plastic liner to prevent moisture ingress. All accessories are individually wrapped in anti-static bags and secured within the main packaging.

Additional Information

The Karl Storz ENDOFLATOR 50 (UI500) is a CE-marked and FDA-cleared medical device classified as a Class IIa laparoscopic insufflator under the European Medical Device Regulation (MDR 2017/745) and FDA 21 CFR Part 876.1500. The device complies with all relevant international standards including IEC 60601-1 (Medical electrical equipment - General requirements for basic safety and essential performance), IEC 60601-2-18 (Particular requirements for the basic safety and essential performance of endoscopic equipment), ISO 13485 (Medical devices - Quality management systems), and ISO 14971 (Medical devices - Application of risk management). The insufflator is manufactured in Germany under strict quality control processes and has received multiple international certifications including Health Canada approval and Japan MHLW certification. The device is compatible with all standard laparoscopic procedures including diagnostic laparoscopy, cholecystectomy, appendectomy, hernia repair, gynecological procedures, and urological surgeries. Clinical benefits include reduced postoperative pain, faster recovery times, and improved surgical outcomes due to precise pneumoperitoneum control. The device supports integration with hospital information systems for data collection and quality improvement initiatives. The insufflator's compact design and ergonomic controls enhance operating room efficiency and reduce procedure setup times. The device has been used in over 2,000 clinical procedures across multiple healthcare facilities with consistently positive outcomes. The ENDOFLATOR 50 is part of Karl Storz's comprehensive endoscopic surgery portfolio, ensuring compatibility with their full range of laparoscopic instruments and imaging systems. The device includes a built-in data logging system that records all operational parameters for quality assurance and regulatory compliance purposes.

Location

425, Marketview, Irvine, California, United States of America, 92602

Reviews

⭐ 0 out of 5 (0 reviews)

Seller

Irvine, United States of America

Listed by: Dr. Louay Othman