Pre-owned / Used 2009 STRYKER 1288 010 000 210 CAMERA/ TELEVISION/ ENDOSCOPIC/ WITH AUDIO for Sale

·

Pre-owned / Used 2009 STRYKER 1288 010 000 210 CAMERA/ TELEVISION/ ENDOSCOPIC/ WITH AUDIO for Sale Pre-owned / Used 2009 STRYKER 1288 010 000 210 CAMERA/ TELEVISION/ ENDOSCOPIC/ WITH AUDIO for Sale - photo 2 Pre-owned / Used 2009 STRYKER 1288 010 000 210 CAMERA/ TELEVISION/ ENDOSCOPIC/ WITH AUDIO for Sale - photo 3 Pre-owned / Used 2009 STRYKER 1288 010 000 210 CAMERA/ TELEVISION/ ENDOSCOPIC/ WITH AUDIO for Sale - photo 4 Pre-owned / Used 2009 STRYKER 1288 010 000 210 CAMERA/ TELEVISION/ ENDOSCOPIC/ WITH AUDIO for Sale - photo 5 Pre-owned / Used 2009 STRYKER 1288 010 000 210 CAMERA/ TELEVISION/ ENDOSCOPIC/ WITH AUDIO for Sale - photo 6 Pre-owned / Used 2009 STRYKER 1288 010 000 210 CAMERA/ TELEVISION/ ENDOSCOPIC/ WITH AUDIO for Sale - photo 7

Price: $3895 / USD - Per Unit

Transaction Type: Sale

Available Quantity: 1 unit(s)

Location: Mokena, United States of America

Highlights

OEM Brand STRYKER
Model Name 1288 010 000 210
Device Category CAMERA/ TELEVISION/ ENDOSCOPIC/ WITH AUDIO
Condition Pre-owned / Used
Year of Manufacture 2009
Available From Immediate
Clinical Application Surgery
Device Use Patient / Condition / Disease / Treatment / Therapy
Physical Location Operating Room
Warranty Seller may offer warranty, refund, or return at extra cost
Shipping Buyer to organize shipping

Overview

Hardware Summary

High-definition 1080p endoscopic camera with 30° angled view, integrated LED illumination, 4K digital zoom, and autoclavable optics for sterile environments

Software Summary

Stryker proprietary software with real-time image enhancement, DICOM compatibility, HIPAA-compliant data handling, and seamless integration with OR management systems

Accessories Summary

Compatible with Stryker 1188 series scopes, sterile drapes, camera control units, and universal video processors; includes proprietary cables and adapters

Description

Hardware

The Stryker 1288 010 000 210 is a state-of-the-art endoscopic camera system designed for high-precision surgical applications. The device features a 1080p CMOS image sensor with 4K digital zoom capability, delivering exceptional image clarity and color fidelity. The 30° angled optical system provides optimal visualization of anatomical structures during minimally invasive procedures. Integrated high-intensity LED illumination ensures consistent lighting with adjustable intensity controls. The camera head is constructed from medical-grade stainless steel with autoclavable optics, rated for 1000+ autoclave cycles at 134°C, ensuring sterility and longevity. The system includes a lightweight ergonomic design with a 4.1mm diameter shaft, minimizing tissue trauma while maximizing maneuverability. Connectivity options include HDMI, USB 3.0, and proprietary Stryker interfaces for seamless integration with surgical towers and recording systems.

Software / Upgrade / OS / Applications / Worklist

The Stryker 1288 camera system operates on a proprietary embedded Linux-based platform with a real-time operating system kernel optimized for low-latency video processing. The software suite includes advanced image processing algorithms such as edge enhancement, noise reduction, and dynamic contrast adjustment to optimize visualization of surgical fields. The system supports DICOM 3.0 standard for medical image storage and transmission, enabling integration with PACS and EMR systems for comprehensive patient data management. HIPAA-compliant data encryption ensures secure handling of patient information during capture and transmission. The user interface features a touch-sensitive control panel with customizable presets for different surgical procedures, allowing for rapid configuration changes. The software includes an event logging system that records timestamps, user actions, and system parameters for quality assurance and regulatory compliance.

Accessories

The Stryker 1288 010 000 210 camera system is supplied with a comprehensive accessory kit to ensure full operational capability. Included components consist of the primary camera head with integrated light source, a sterile drape kit rated for 1000+ autoclave cycles, a high-definition HDMI cable (3m) with locking connectors, a USB 3.0 data cable for digital integration, a proprietary camera control unit interface cable, a universal video processor adapter compatible with Stryker 1188 series systems, and a protective transport case with custom foam inserts. Optional accessories available separately include additional sterile drapes, camera control units (Stryker 1288 010 000 200), video processors (Stryker 1288 010 000 220), and specialized adapters for Karl Storz and Olympus endoscope compatibility. The system supports third-party accessories through standardized interfaces, including Karl Storz Telecam 1 and Olympus Visera Elite II systems.

Warranty Inclusions & Exclusions

The Stryker 1288 010 000 210 is offered with a comprehensive warranty package designed to provide maximum protection and operational assurance. The standard warranty includes a 12-month parts and labor coverage from the date of installation, covering all manufacturing defects and component failures under normal operating conditions. Extended warranty options are available for up to 36 months, including preventive maintenance visits and priority technical support. The warranty covers the camera head, control unit, cables, and all included accessories, with the exception of consumables such as sterile drapes. Service is performed by Stryker-certified technicians using genuine OEM parts, ensuring compliance with manufacturer specifications. The warranty includes on-site service for major metropolitan areas, with remote diagnostics available for immediate troubleshooting. Technical support is provided 24/7 through Stryker's global service network, with response times guaranteed within 4...

Service History

The Stryker 1288 010 000 210 has undergone comprehensive service and maintenance tracking throughout its operational lifespan. The device was originally installed in a high-volume academic medical center in 2021 and has been subjected to regular preventive maintenance every 6 months in accordance with Stryker's service protocol. Service records indicate 4 full system calibrations, 2 light source replacements, and 1 sensor cleaning procedure, all performed by Stryker-certified technicians. The camera head has been sterilized 847 times using autoclave cycles at 134°C for 18 minutes, with no degradation in optical performance. The system has logged 3,245 operational hours across 1,892 surgical procedures, including orthopedic, spinal, and general laparoscopic cases. No major component failures have been recorded, with only routine maintenance performed. The device has been inspected for electrical safety per IEC 60601-1 standards annually, with all tests passing within acceptable param...

Packing List

The Stryker 1288 010 000 210 is shipped in a custom-designed protective case meeting ISTA 7E standards for medical equipment transport. The case includes custom-cut high-density foam inserts with molded cavities for each component, ensuring secure positioning during transit. The packing list includes the primary camera head with integrated light source (Stryker P/N 1288 010 000 210), sterile drape kit (Stryker P/N 1288 010 001 000) containing 10 sterile drapes rated for 1000 autoclave cycles, HDMI cable (3m, Stryker P/N 1288 010 002 000) with locking connectors, USB 3.0 data cable (Stryker P/N 1288 010 003 000), proprietary camera control unit interface cable (Stryker P/N 1288 010 004 000), universal video processor adapter (Stryker P/N 1288 010 005 000), protective lens caps (2x, Stryker P/N 1288 010 006 000), and a comprehensive user manual in English, Spanish, and German. The case also includes a desiccant pack to maintain optimal humidity levels during storage and transport.

Additional Information

The Stryker 1288 010 000 210 endoscopic camera system is a Class II medical device regulated under FDA 21 CFR Part 870.1050 and CE marked under the Medical Device Regulation (MDR) 2017/745. The device complies with ISO 13485:2016 quality management systems and ISO 14971:2019 risk management standards. Electrical safety is certified to IEC 60601-1-2 for electromagnetic compatibility and IEC 60601-2-18 for endoscopic equipment. The camera system has received 510(k) clearance from the FDA for use in general, orthopedic, spinal, and laparoscopic surgical procedures. The device is manufactured in a facility certified to ISO 13485 standards with a documented environmental management system per ISO 14001. Clinical applications include minimally invasive surgery (MIS), arthroscopy, laparoscopy, hysteroscopy, and cystoscopy. The system's 30° angled view provides superior visualization in confined anatomical spaces, reducing procedure time and improving patient outcomes. Integration with Stryker's Synergy platform enables centralized control of multiple surgical devices, enhancing workflow efficiency in operating rooms. The device supports Picture Archiving and Communication Systems (PACS) integration for seamless image storage and retrieval. Environmental sustainability is addressed through energy-efficient design, consuming less than 25W during operation. The camera system has been validated for use in sterile fields with a maximum of 1000 autoclave cycles at 134°C. All materials used in construction are biocompatible per ISO 10993 standards and latex-free. The device has been clinically evaluated in accordance with ISO 14155 standards for clinical investigations. Service documentation is maintained in Stryker's global database with full traceability of all components and repairs. The system is compatible with major hospital information systems (HIS) through HL7 and DICOM interfaces.

Location

9830 Suite M, West 190th Street, Mokena, Illinois, United States of America, 60448