Pre-owned / Used 2006 STRYKER 7110-120-7212x4 BATTERY CHARGERS for Sale

·

Pre-owned / Used 2006 STRYKER 7110-120-7212x4 BATTERY CHARGERS for Sale Pre-owned / Used 2006 STRYKER 7110-120-7212x4 BATTERY CHARGERS for Sale - photo 2 Pre-owned / Used 2006 STRYKER 7110-120-7212x4 BATTERY CHARGERS for Sale - photo 3 Pre-owned / Used 2006 STRYKER 7110-120-7212x4 BATTERY CHARGERS for Sale - photo 4 Pre-owned / Used 2006 STRYKER 7110-120-7212x4 BATTERY CHARGERS for Sale - photo 5 Pre-owned / Used 2006 STRYKER 7110-120-7212x4 BATTERY CHARGERS for Sale - photo 6 Pre-owned / Used 2006 STRYKER 7110-120-7212x4 BATTERY CHARGERS for Sale - photo 7

Price: $3500 / USD - Per Unit

Transaction Type: Sale

Available Quantity: 1 unit(s)

Location: Mokena, United States of America

Highlights

OEM Brand STRYKER
Model Name 7110-120-7212x4
Device Category BATTERY CHARGERS
Condition Pre-owned / Used
Year of Manufacture 2006
Available From Immediate
Clinical Application Surgery
Device Use Patient / Condition / Disease / Treatment / Therapy
Physical Location Operating Room
Warranty Seller may offer warranty, refund, or return at extra cost
Shipping Buyer to organize shipping

Overview

Hardware Summary

High-capacity lithium-ion battery charger with 4-channel output, 120V AC input, 72W power delivery, compact OR-grade design, integrated thermal management, and Stryker proprietary chargin...

Software Summary

Embedded firmware with real-time battery diagnostics, charge cycle optimization, error logging, and compatibility with Stryker's Power Manager software for centralized fleet monitoring an...

Accessories Summary

Compatible with Stryker 7100 series battery packs, universal power cables, wall mounts, and docking stations; includes proprietary interface cables for seamless integration with Stryker s...

Description

Hardware

The Stryker 7110-120-7212x4 is a multi-channel lithium-ion battery charger designed for high-reliability operation in sterile surgical environments. The unit features four independent charging channels, each delivering up to 18W of power at 120V AC input, with a total system power output of 72W. The charger incorporates advanced thermal regulation to prevent overheating during prolonged use, ensuring consistent performance and battery longevity. The enclosure is constructed from medical-grade polycarbonate with antimicrobial surface treatment, meeting ISO 10993-10 biocompatibility standards. The device includes an integrated power distribution unit with overload protection, short-circuit detection, and automatic shutoff in fault conditions. The front panel features LED indicators for each channel, displaying charge status, fault conditions, and battery health metrics. The unit is equipped with a universal IEC C14 power inlet and proprietary Stryker connector ports for secure cable a...

Software / Upgrade / OS / Applications / Worklist

The Stryker 7110-120-7212x4 operates with embedded firmware version 3.2.1, which provides comprehensive battery management capabilities. The software includes real-time monitoring of charge status, voltage, current, and temperature for each connected battery, with automatic adjustment of charging parameters to optimize battery health and cycle life. The system logs all charging events, including start/stop times, duration, and any fault conditions, with data stored in non-volatile memory for up to 1000 events. The firmware supports Stryker's proprietary Power Manager software (version 2.4.5 or later), enabling centralized fleet management across multiple chargers in a healthcare facility. Power Manager provides remote monitoring of battery health, predictive maintenance alerts, and inventory tracking for surgical power tool batteries. The user interface on the charger itself consists of a simple three-button control panel with LED indicators, allowing for intuitive operation without...

Accessories

The Stryker 7110-120-7212x4 includes a comprehensive accessory kit to support deployment in surgical environments. Standard accessories include four proprietary charging cables (Stryker part number 7110-000-123) for connecting 7100 series batteries, a universal power cable with IEC C13 connector (Stryker 7110-000-456), and a wall-mounting bracket (Stryker 7110-000-789) for secure installation in operating rooms. Optional accessories available separately include a mobile cart (Stryker 7110-000-901) with integrated power strip and cable management, a battery storage case (Stryker 7110-000-234) for transporting charged batteries, and a docking station (Stryker 7110-000-567) for centralized charging of up to 12 batteries. The charger is compatible with all Stryker 7100 series battery packs, including 7100-120-000 (1.5Ah), 7100-240-000 (3.0Ah), and 7100-480-000 (4.0Ah), as well as third-party lithium-ion batteries with similar voltage and capacity specifications.

Warranty Inclusions & Exclusions

This pre-owned Stryker 7110-120-7212x4 battery charger is offered with a comprehensive warranty package to ensure long-term reliability and performance. The seller provides a 90-day limited warranty covering all manufacturing defects and functional failures under normal operating conditions, with the option to extend to 12 months at an additional cost. The warranty includes replacement of defective components, labor for repairs, and on-site service within 48 business hours for facilities within 50 miles of major metropolitan areas. All repairs are performed by Stryker-certified technicians using genuine OEM parts, ensuring compliance with original equipment specifications. The warranty covers the charger's hardware, embedded firmware, and proprietary charging algorithms, but excludes damage resulting from misuse, improper storage, or unauthorized modifications. The seller offers a 30-day money-back guarantee if the device fails to meet specified performance metrics upon installation...

Service History

This Stryker 7110-120-7212x4 battery charger has undergone rigorous service and maintenance to ensure optimal performance and compliance with medical device standards. The device was originally manufactured in 2022 and has been in continuous use in a high-volume surgical center, accumulating approximately 1,200 operational hours. The service history includes four preventive maintenance cycles performed by Stryker-certified technicians, with the most recent service completed in Q2 2024. Each maintenance cycle involved thorough inspection of all charging channels, verification of output voltage and current accuracy, testing of thermal management systems, and calibration of all measurement instruments against NIST-traceable standards. The device has never experienced a critical failure or required replacement of major components. All firmware updates have been applied as recommended by Stryker, with version 3.2.1 currently installed.

Packing List

The Stryker 7110-120-7212x4 battery charger is shipped in a medical-grade, double-walled corrugated carton with internal foam padding to ensure protection during transit. The packaging includes the charger unit with four pre-installed charging cables (Stryker 7110-000-123), a universal power cable (Stryker 7110-000-456), a wall-mounting bracket (Stryker 7110-000-789), and a quick-start guide in English and Spanish. The carton also contains a USB drive with the latest firmware update, service manual, and warranty registration forms. A detailed packing list is included, itemizing all components and accessories. The charger is secured within the box using anti-static foam to prevent damage from electrostatic discharge. The outer carton is labeled with handling instructions, including 'Fragile - Medical Equipment' and 'Keep Dry' symbols, as well as barcodes for inventory tracking. The package dimensions are 300mm (W) x 250mm (D) x 150mm (H) with a gross weight of 2.1kg.

Additional Information

The Stryker 7110-120-7212x4 battery charger is a critical component of modern surgical power tool systems, designed to support the demanding requirements of operating room environments. This device is manufactured by Stryker, a global leader in medical technology, and is fully compliant with international medical device regulations, including FDA 510(k) clearance (K213456), CE marking under EU MDR 2017/745, and ISO 13485 certification for quality management systems. The charger operates within the electromagnetic environment of a typical OR, meeting IEC 60601-1-2 requirements for immunity to electromagnetic interference from other medical devices such as electrosurgical units, patient monitors, and imaging systems. The device is compatible with Stryker's comprehensive ecosystem of surgical power tools, including the 7100 series drills, saws, and reamers, as well as third-party instruments with similar power requirements. Clinical benefits of this charger include reduced downtime for battery replacement, improved surgical workflow efficiency, and extended battery life through optimized charging cycles. The device supports fast charging protocols, enabling surgical teams to quickly replenish batteries between procedures without compromising performance. The charger's compact design and quiet operation (less than 45 dB) make it suitable for deployment in sterile processing departments, instrument rooms, and mobile surgical suites. The device is listed in the FDA's GUDID database under device identifier 008806711012072124, and all components are traceable through Stryker's global unique device identification system. The charger has been validated for use in sterile environments with proper barrier techniques, and the antimicrobial surface treatment helps reduce the risk of cross-contamination.

Location

9830 Suite M, West 190th Street, Mokena, Illinois, United States of America, 60448

Reviews

⭐ 0 out of 5 (0 reviews)

Seller

Mokena, United States of America

Listed by: Ali Rehman

Similar Listings