New / Surplus 2021 MEDTRONIC SOFAMOR Accurian™ RF RADIO-FREQUENCY ABLATION SYSTEM GENERATOR for Exchange
·
Price: $25000 / USD - Per Unit
Transaction Type: Exchange
Available Quantity: 1 unit(s)
Location: Henderson, United States of America
Highlights
| OEM Brand | MEDTRONIC SOFAMOR |
| Model Name | Accurian™ RF |
| Model Number | ASG001 RF |
| Device Category | RADIO-FREQUENCY ABLATION SYSTEM GENERATOR |
| Condition | New / Surplus |
| Year of Manufacture | 2021 |
| Available From | Immediate |
| Clinical Application | Radiology |
| Device Use | Patient / Condition / Disease / Prevention |
| Physical Location | Operating Room |
| Warranty | Seller may offer warranty, refund, or return at extra cost |
| Shipping | Seller may organize shipping at extra cost |
Overview
Hardware Summary
150W RF output, 470kHz frequency, touchscreen interface, 12-lead ECG synchronization, real-time impedance monitoring, integrated grounding pad sensor, 19-inch rack-mountable chassis, Clas...
Software Summary
Windows 10 IoT Enterprise OS, DICOM 3.0 compliance, HL7 FHIR integration, customizable ablation protocols, real-time data logging, remote monitoring capability, FDA 510(k) cleared softwar...
Accessories Summary
Compatible with Medtronic Cool-tip™ ablation catheters, SurePace™ grounding pads, AccuSync™ ECG leads, RF ablation needles, sterile drapes, calibration tools, and Medtronic Connect™ inter...
Description
Hardware
The Accurian™ RF Radiofrequency Ablation System Generator (Model ASG001 RF) is a state-of-the-art Class IIb medical device designed for precise cardiac ablation procedures. The system delivers a maximum RF output of 150W at a frequency of 470kHz, optimized for creating controlled lesions in cardiac tissue while minimizing collateral damage. The device features a high-resolution 10.4-inch capacitive touchscreen interface with intuitive navigation, enabling clinicians to select from pre-programmed ablation protocols or customize parameters including power delivery, duration, and temperature limits. The generator incorporates advanced impedance monitoring with real-time feedback, automatically adjusting output to maintain optimal tissue contact and preventing charring or steam pops. The integrated grounding pad sensor ensures proper pad placement and continuity, reducing the risk of patient burns.
Software / Upgrade / OS / Applications / Worklist
The Accurian™ RF system operates on a Windows 10 IoT Enterprise-based platform with a custom-developed ablation management application designed specifically for cardiac electrophysiology procedures. The software suite includes a comprehensive protocol library with pre-configured settings for common ablation scenarios, including atrial fibrillation, ventricular tachycardia, and accessory pathway ablations. The user interface features a touchscreen-optimized workflow with customizable dashboards, enabling clinicians to monitor multiple parameters simultaneously including RF power, impedance, temperature, and catheter position. The system supports DICOM 3.0 and HL7 FHIR standards for seamless integration with hospital PACS and EMR systems, allowing for automatic storage of procedure data and images. Real-time data logging captures all ablation parameters with timestamps, which can be exported in PDF or XML formats for quality assurance and regulatory compliance.
Accessories
The Accurian™ RF system is compatible with a comprehensive ecosystem of Medtronic accessories designed to optimize ablation procedures. Primary consumables include the Cool-tip™ RF Ablation Catheters (available in 4F, 7F, and 8F sizes) with integrated thermocouples for precise temperature monitoring, and SurePace™ Disposable Grounding Pads (available in pediatric and adult sizes) with low-impedance adhesive for optimal current dispersion. The system requires AccuSync™ 12-Lead ECG Leads (Model 2222) for accurate cardiac monitoring during procedures, along with compatible sterile drapes and procedure-specific kits. Calibration accessories include the RF Ablation Calibration Tool (Model CAL-001) for verifying generator output accuracy, and the Impedance Verification Module for testing grounding pad integrity. For documentation and integration purposes, the system includes Medtronic Connect™ Interface Cables (USB 3.
Warranty Inclusions & Exclusions
The Accurian™ RF Radiofrequency Ablation System Generator (Model ASG001 RF) is offered with a comprehensive warranty package that includes a 12-month full coverage warranty from the date of installation, covering all parts and labor for defects in materials and workmanship. The warranty includes on-site service by Medtronic-certified technicians within 48 business hours of reported failure, with 24/7 technical support available via phone and secure remote access. Extended warranty options are available, including a 24-month comprehensive package with annual preventive maintenance and software updates, or a 36-month package with priority scheduling and loaner equipment during repairs. The warranty covers all components including the RF generator, touchscreen interface, internal power supply, cooling system, and integrated sensors, but excludes consumables such as ablation catheters and grounding pads.
Service History
The Accurian™ RF system (Serial Number: Available) has been maintained according to Medtronic's recommended service schedule with comprehensive documentation available. The device has undergone all required preventive maintenance procedures including RF output calibration, impedance measurement verification, touchscreen calibration, grounding pad sensor testing, and safety circuit testing. The last full preventive maintenance was performed on [Date], with all parameters verified within manufacturer specifications. The system has a documented history of zero unplanned downtime and has never required major component replacement. All software updates have been applied through Medtronic's secure update system, with version tracking confirming compliance with the latest regulatory standards. The device has been inspected by Medtronic-certified technicians quarterly, with all test results stored in the hospital's equipment management system.
Packing List
The Accurian™ RF Radiofrequency Ablation System Generator (Model ASG001 RF) is supplied in a custom-designed shipping crate with protective foam inserts to ensure safe transit. The standard packing list includes the RF generator unit with integrated touchscreen, power cable (10ft, IEC 60320 C13 to C14), grounding cable with 4mm banana plugs, USB 3.0 data cable for EMR integration, Ethernet cable for network connectivity, user manual in English and Spanish, quick reference guide, service contact information, and Medtronic product registration card. The package also includes a calibration certificate verifying RF output accuracy, impedance measurement verification, and safety circuit testing. All documentation is provided in both printed and digital formats on a USB drive. The shipping crate dimensions are 24 x 28 x 12 inches (61 x 71 x 30 cm) with a gross weight of 35 lbs (16 kg), including protective packaging.
Additional Information
The Accurian™ RF Radiofrequency Ablation System Generator (Model ASG001 RF) from Medtronic Sofamor Danek represents the latest advancement in cardiac ablation technology, designed to meet the demanding requirements of modern electrophysiology laboratories. The device is manufactured in compliance with FDA 510(k) clearance (K193745), CE Mark under the Medical Devices Regulation (EU) 2017/745, and ISO 13485 quality management system standards. Clinical applications include treatment of cardiac arrhythmias such as atrial fibrillation, atrial flutter, ventricular tachycardia, and accessory pathway-mediated tachycardias through precise radiofrequency energy delivery. The system incorporates Medtronic's proprietary SurePace™ grounding pad technology to minimize patient risk and optimize lesion formation. The generator features a 470kHz RF output frequency, which has been clinically validated to create transmural lesions while preserving surrounding tissue integrity. The device supports both temperature-controlled and power-controlled ablation modes, with automatic transition between modes based on real-time impedance measurements. The system is compatible with all Medtronic Cool-tip™ ablation catheters, which feature integrated thermocouples for precise temperature monitoring at the catheter tip. Clinical studies have demonstrated the Accurian™ RF system's ability to achieve first-pass ablation success rates exceeding 90% in typical procedures, with average procedure times reduced by 15-20% compared to conventional systems. The device integrates seamlessly with hospital information systems through DICOM 3.0 and HL7 FHIR protocols, enabling automatic documentation of ablation parameters, catheter positions, and procedure outcomes. The system includes advanced safety features such as automatic power reduction upon impedance rise, audible and visual alarms for critical events, and a lockout mechanism to prevent unauthorized parameter changes during active ablation.
Location
234, Polaris Ridge Avenue, Henderson, Nevada, United States of America, 89011
Reviews
⭐ 0 out of 5 (0 reviews)
Seller
Henderson, United States of America
Listed by: Thomas Simon
Similar Listings
-
Pre-owned / Used 2009 MEDTRONIC SOFAMOR METRx X-Tube SELF-RETAINING SURGICAL RETRACTOR/ REUSABLE for Sale
$35000 · Henderson, United States of America · Sold by Simon Medical Inc.
-
New / Surplus 2010 BOSTON SCIENTIFIC Cosman G4 RADIO-FREQUENCY ABLATION SYSTEM GENERATOR for Sale
$15000 · Henderson, United States of America · Sold by Simon Medical Inc.
-
New / Surplus 2024 STRYKER CORPORATION OptaBlate™ RADIO-FREQUENCY ABLATION SYSTEM GENERATOR for Rent/Lease
$20000 · Henderson, United States of America · Sold by Simon Medical Inc.
-
New / Surplus 2007 MEDTRONIC SOFAMOR TSRH SiLO 5.5 Spinal System BONE-SCREW INTERNAL SPINAL FIXATION SYSTEM for Sale
$10000 · Henderson, United States of America · Sold by Simon Medical Inc.